Electrically Operated Dosing Pump Series EML

Electrically Operated Dosing Pump Series EML

INTELLIGENT DOSING PUMP WITH SOLENOID DRIVE

The EML dosing pump is a new version of a solenoid diaphragm pump with microprocessor control and variable frequency. It features all the characteristics of the MLS models, with additional Modbus 485 control and an advanced display screen. WRS continuously invests in upgrading our pumps to meet current market demands and the evolving needs of our valued customers. As industries move towards more automated systems, the Eignal series is your best choice when looking for reliable, durable, and high‑performance dosing pumps.

Your new intelligent solenoid dosing pump EML from WRS has a nominal flow rate of 1–20 L/h, with a corresponding maximum outlet pressure of 10–1 bar. The pump’s output can be adjusted according to the pulse frequency switch. It offers a simple structure, low power consumption, precise measurement, and a new screen display for an electromagnetic diaphragm dosing pump.

Features

EML Dosing Pump
  • Compact size and easy installation
  • Simple control design—operated with just three buttons
  • Specifically designed for handling aggressive liquids
  • Various material options for different applications
  • Controlled flow in both operating and non‑operating states
  • Easy air release or sampling from the system via an air release valve directly at the outlet
  • Compact modular design
  • Simple LED display
  • Double‑ball check valve for easy maintenance
  • Accessories included in the delivery package
  • Wear‑resistant solenoid drive, no bearings
  • New high‑performance circuit board with a new design. Perfectly matches the magnetic drive, providing strong driving power

GENERAL PUMP TECHNICAL SPECIFICATIONS

Model EML
Flow rate (L/h) 1–20 L/h
Pressure (bar) 1–10
Pump head material Standard: PVC. Optional: PVDF, SS316
Operation mode Continuous or intermittent
Number of pump heads 1
Connection type Compression fitting for hose Ø5×8
Flow adjustment method Frequency control
Flow rate display method Digital display
Remote control No
Negative suction 2 m
Inlet/outlet valve type Double ball valve
Protection rating IP65
Insulation class F
Accuracy ±2% in steady state
Weight Gross weight: 3.2 kg. Net weight: 4.2 kg
Drive type Internal electromagnetic drive
Input power 28 W
Required power supply 1Ph 240V 50Hz / 1Ph 110V 60Hz
Strokes per minute 80–180

DIAPHRAGM DETAILS

Diameter (mm) 60–84
Material Layer 1: PTFE
Layer 2: EPDM rubber
Layer 3: 3.0 mm SUS304
Layer 4: Nylon fiber
Layer 5: EPDM rubber

FLUID PARAMETERS

Fluid temperature range –15 ℃ to 60 ℃
Viscosity range 0.3–1000 cps

ENVIRONMENT PARAMETERS

Ambient temperature range –10 ℃ to +45 ℃
Outdoor installation Yes, with shelter protection from rain and direct sunlight

STANDARD FACTORY EXPORT SET

The standard package of the electromagnetic dosing pump series ML/MLS includes all items listed below. If any item is missing or damaged, please contact your shipping company or reach out to us.

Standard Export Set

MODEL SELECTION

Model Flow (L/h) Pressure (bar) Stroke/min Diaphragm diameter (mm) Weight (kg)
EML0001 1 10 80 34 3.2
EML0002 2 10 140
EML0004 4 8 180
EML0005 5 5 140 41
EML0008 8 4 170
EML0010 10 3 130 51 4.2
EML0012 12 2 150
EML0015 15 2 160

MATERIAL SELECTION

Pump head material Diaphragm Valve seat Valve ball Inlet Outlet
PVC PTFE Viton rubber Ceramic PE PE
PVDF PTFE Viton rubber Ceramic PE PE
SS304 PTFE SS304 SS304 SS304 SS304
SS316 PTFE SS316 SS316 SS316 SS316

DIMENSIONS (mm)

Model Pump Head Material Connection A B
EML0001–EML0020 PVC Φ5×8 PE Hose Compression Fitting 18 175
EML0001–EML0020 PVDF / SS304 / SS316 Φ5×8 PE Hose Compression Fitting 17 158

OPERATING INSTRUCTIONS

Before starting the pump, ensure:

  • The power supply matches the pump specifications (1Ph 240V 50Hz or 1Ph 110V 60Hz).
  • All connections are tight and leak‑free.
  • The fluid type and viscosity are within the specified range (0.3–1000 cps).
  • Ambient temperature is within –10 ℃ to +45 ℃.
  • For outdoor use, the pump is protected from rain and direct sunlight.

To adjust the flow rate:

  • Press the SET button to enter the configuration mode.
  • Use the UP and DOWN buttons to select the desired flow rate (1–20 L/h).
  • Confirm the setting by pressing SET again.

MAINTENANCE

  • Regularly inspect the diaphragm for wear or damage (recommended every 6 months).
  • Clean the inlet and outlet valves to prevent clogging.
  • Check the tightness of all connections periodically.
  • Ensure the pump head material is compatible with the fluid being pumped.
  • Store the pump in a dry place when not in use.

WARRANTY

The EML dosing pump comes with a 12‑month warranty from the date of purchase. The warranty covers manufacturing defects but does not include damage caused by improper use, lack of maintenance, or unauthorized modifications.



TROUBLESHOOTING

Issue Possible Cause Solution
Low flow rate Clogged inlet/outlet valve Clean the valves and check for obstructions.
Pump not starting Incorrect power supply Verify voltage and frequency match specifications.
Leaking pump head Damaged diaphragm Replace the diaphragm.
Unstable flow Air in the system Release air through the air release valve.

SAFETY INFORMATION

  • Do not operate the pump without fluid in the line (dry running may damage the diaphragm).
  • Wear protective equipment when handling aggressive fluids.
  • Disconnect power before performing maintenance.
  • Ensure proper grounding of the pump.
  • Do not exceed maximum pressure ratings (1–10 bar).