Disinfection Tunnel
The Poliplast disinfection tunnel is designed for high-throughput mass disinfection and testing (temperature measurement) to reduce the risk of viral and infection transmission. The fully automatic intelligent control system significantly reduces human workload related to monitoring and safety operations and minimizes the risk for personnel working in crowded areas.
The disinfection tunnel is equipped with high-precision industrial infrared spectral sensors, allowing fast and reliable non-contact body temperature measurement. If the temperature exceeds the limit, the system triggers visual and audio alarms.
Eliminates up to 99% of all known viruses on clothing and skin in just 5 seconds!
The disinfection tunnel is equipped with high-precision industrial infrared spectral sensors, allowing fast and reliable non-contact body temperature measurement. If the temperature exceeds the limit, the system triggers visual and audio alarms.
Просмотр 360°
The disinfection process occurs in stages:
Face recognition, mask detection, verification, and temperature measurement. If parameters are out of range, the system alerts the operator.
Hand disinfection. The temperature measurement zone is equipped with a hand sanitizer with non-contact induction spray.
Full body disinfection. The disinfectant spray activates when a person enters. The disinfectant is food-grade, safe for human health, and widely used for disinfecting food and water.
| Type | Disinfection Tunnel | Hand Disinfection Type | Separate Disinfectant Sprayer |
|---|---|---|---|
| Operating Voltage | ~220V | Temperature Channel Length | 64 cm |
| Rated Power | 900 W | Human Detection Mode | Microwave detection |
| Operating Environment | 0 ~ 35 ℃ | Body Temperature Measurement Method | Infrared spectrum (real-time accurate detection) |
| Equipment Material | Cold-rolled steel sheet | Body Temperature Measurement Distance | 10–20 cm |
| Disinfection Method | Automatic spray device | Temperature Data Collection | Forehead, inner wrist (non-contact) |
| Spray Channel Length | 116 cm | Temperature Measurement Accuracy | ± 0.5 ℃ at room temperature |
| Spray Method | Ultrasonic spray | Body Temperature Detection Time | Body temperature detection time |
| Spray Control Method | Induction, delayed stop, 4 nozzles | Body Temperature Measurement Range | 34 ~ 45 ℃ |
| Spray Efficiency | 3–6 kg/h | Disinfectant Tank Capacity | 20 L |
| Spray Zone Protection | PVC door curtain | Recommended Spray Disinfection Time | 5–15 seconds |
| Disinfectant Type | 100–400 ppm diluted chlorine dioxide solution, 200 ppm diluted hypochlorous acid solution | ||